Divertors and mechanical switches
Walvoil
Product code: 2481
G3/8–G1
maximum working pressure: 315 bar
maximum flow rate: 280 l/min
Walvoil
Product code: 2485
2, 3, 6, 8 and 12-way
G1/4–G3/4
maximum working pressure: 315 bar
maximum flow rate: 140 l/min
Walvoil
Product code: 2486
6, 8 and 10-way
G1/4, G3/8, G1/2
maximum working pressure: 315 bar
maximum flow rate: 80 l/min
Walvoil
Product code: 2483
G3/8
maximum working pressure: 210 bar
maximum flow rate: 25 l/min
Walvoil
Product code: 2487
G3/8
maximum working pressure: 250 bar
maximum flow rate: 80 l/min
Walvoil
Product code: 2484
G1/2
maximum working pressure: 315 bar
maximum flow rate: 80 l/min
Walvoil
Product code: 2482
G3/8–G1 1/2
maximum working pressure: 315 bar
maximum flow rate: 280 l/min
Walvoil
Product code: 5268
G1/4, 7/16–20 UNF
maximum working pressure: 100 bar
maximum flow rate: 10 l/min
Ponar
Product code: 741
G1/2
maximum working pressure: 350 bar
maximum flow rate: 50 l/min
Ponar
Product code: 742
G3/4
maximum working pressure: 350 bar
maximum flow rate: 100 l/min
Ponar
Product code: 739
G3/8
maximum working pressure: 350 bar
maximum flow rate: 55 l/min
Ponar
Product code: 737
G1/2
maximum working pressure: 350 bar
maximum flow rate: 55 l/min
Ponar
Product code: 740
G1/2
maximum working pressure: 350 bar
maximum flow rate: 85 l/min
Ponar
Product code: 736
G1/2
maximum working pressure: 350 bar
maximum flow rate: 85 l/min
Ponar
Product code: 738
G1/2
maximum working pressure: 350 bar
maximum flow rate: 85 l/min
Ponar
Product code: 743
G3/8, G1/2
up to 5 sections
maximum working pressure: 350 bar
maximum flow rate: 50 l/min
Ponar
Product code: 744
G1/2, G3/4
up to 5 sections
maximum working pressure: 350 bar
maximum flow rate: 80 l/min
Ponar
Product code: 745
G3/8, G1/2
up to 5 sections
maximum working pressure: 350 bar
maximum flow rate: 50 l/min
Ponar
Product code: 735
M14x1.5
maximum working pressure: 300 bar
maximum flow rate: 60 l/min
Diverters and mechanical switches
Principle work and application of diverters
Diverters (three-way cranes) are directional control valves that are used for special requirements of hydraulic drive operation, for example, the operation of one pump alternately into two independent circuits. Diverters can switch hydraulic system flows at full operating pressure.
Diverters can be three, four and six linear.
Diverters by the type of control:
- with manual control;
- with electromagnetic control;
- with pneumatic control.
Application of mechanical switches
Mechanical switches are used to manually unload the hydraulic circuit or block the movement of the working fluid.