Hydroaccumulators

Housings type B Housings type B

Epoll

Product code: 6185

capacity: 52 or 75 l

maximum working pressure: 360 bar

Housings type ASS Housings type ASS

Epoll

Product code: 6186

capacity: 3–55 l

maximum working pressure: 360 bar

Housings type ASSA Housings type ASSA

Epoll

Product code: 6189

capacity: 1.25–55 l

maximum working pressure: 270 bar

Bladder Accumulators SB16, SB35 and SB40 Bladder Accumulators SB16, SB35 and SB40

Hydac

Product code: 2713

capacity: 2.5–450 l

maximum working pressure: 40 bar

Housings type AB Housings type AB

Epoll

Product code: 6190

capacity: 0.1–1000 l

maximum working pressure: 375 bar

Bladder Accumulators SB690 Bladder Accumulators SB690

Hydac

Product code: 2715

capacity: 1–54 l

maximum working pressure: 690 bar

Back-Up Nitrogen Bottles SN360 and SN600 for accumulators Back-Up Nitrogen Bottles SN360 and SN600 for accumulators

Hydac

Product code: 2716

capacity: 20–50 l  

Piston accumulators SK280 Piston accumulators SK280

Hydac

Product code: 2725

capacity: 0.16–10 l

maximum working pressure: 280 bar

Piston accumulators SK690 Piston accumulators SK690

Hydac

Product code: 2727

capacity: 0.5–50 l

maximum working pressure: 1000 bar

Bellows accumulators SM50 Bellows accumulators SM50

Hydac

Product code: 2724

capacity: 3.8 l

maximum working pressure: 12 bar

Fluid safety valves DBDS for accumulators Fluid safety valves DBDS for accumulators

Epoll

Product code: 6201

M28x1.5, M35x1.5, M45x1.5, M60x2

maximum working pressure: 630 bar

Blocks for relief valve  BPV and BAPV Blocks for relief valve BPV and BAPV

Epoll

Product code: 6202

G1 1/4, G2

maximum working pressure: 400 bar

Charging and shut-off safety block BC Charging and shut-off safety block BC

Epoll

Product code: 6200

G1/2

maximum working pressure: 400 bar

Safety blocks for accumulators BS Safety blocks for accumulators BS

Epoll

Product code: 6203

G3/4, G1 1/4, G2

maximum working pressure: 420 bar

Pulsation dampers TA Pulsation dampers TA

Epoll

Product code: 6211

G1/2–G4

maximum working pressure: 360 bar

Mobile nitrogen charging unit CCA 9/350 Mobile nitrogen charging unit CCA 9/350

Epoll

Product code: 6210

maximum flow rate: 9 l/min

maximum working pressure: 350 bar

tank capacity: 70 l

Adapters for nitrogen charging kits type B2510, B2431, B2511, B2514 Adapters for nitrogen charging kits type B2510, B2431, B2511, B2514

Epoll

Product code: 6622

 5/8 UNF, 1/4 BSP, М28х1.5

Adapters R-A Adapters R-A

Epoll

Product code: 6621

G3/4, G1 1/4, G2

Fluid side adapters TF Fluid side adapters TF

Epoll

Product code: 6204

maximum working pressure: 400 bar

Gas side adapters TG Gas side adapters TG

Epoll

Product code: 6197

maximum working pressure: 400 bar

Burst and fuse disk DR and DF Burst and fuse disk DR and DF

Epoll

Product code: 6196

G1/2

maximum working pressure: 400 bar

Shut off 2-ways valves gas side B2459 Shut off 2-ways valves gas side B2459

Epoll

Product code: 6198

2-way

G3/4

maximum working pressure: 320 bar

Shut off 2-ways valves gas side B2460 Shut off 2-ways valves gas side B2460

Epoll

Product code: 6199

3-way

G3/4

maximum working pressure: 320 bar

Clamps C Clamps C

Epoll

Product code: 6191

Hydraulic accumulators

Hydraulic accumulators are special containers which allows you to accumulate energy, which is then transferred to the hydraulic system through the fluid stream.

Most often, hydraulic accumulators are used to absorb shock, but they are successfully used to perform work in emergency situations (for example, a disconnected hydraulic pump). It is advisable to install a hydraulic accumulator for hydraulics in those systems where there is an occasional need for an increased flow rate that exceeds the average flow rate of a given hydraulic system.

 

Hydraulic accumulator classification

High pressure accumulators can be divided into three groups:

  • balloon: the rubber bulb in this type acts as a gas and liquid separator. With increasing pressure, it contracts, and the fluid enters the battery. The most common type, is able to accumulate up to 1 thousand liters of liquid. It is possible to replace the rubber bulb with a new one;
  • membrane: the most common type. Structurally reminds the previous one, only here a rubber membrane is used. They are used in systems where an instant release of energy is required with a small size of the drive itself. Nitrogen is used as the working gas. The average value of the working pressure is up to 300 bar; it is capable of accumulating up to 10 liters of working fluid;
  • piston: the same principle of operation, only the separator — the piston. The seal material on the piston determines the temperature of the fluid. The battery allows you to accumulate more than 3 thousand liters, and issue a pressure of about 1 thousand atmospheres.

"Motorimpex" company offers you to by high-pressure hydraulic accumulators at reasonable prices. We are official partner, so we guarantee certificated products. Each manufacturer, presented on the website, tests their products. You can be sure in safety and reliable work of this system element.