Control-measuring devices flow sensors purity grade sensors

Flow indicator FI 750 Flow indicator FI 750

Webtec

Product code: 6282

internal thread: G3/4

measuring range: 2–180 l/min

maximum working pressure: 420 bar

Flow indicator FI 1500 Flow indicator FI 1500

Webtec

Product code: 6387

internal thread: G1 1/2

measuring range: 10–400 l/min

maximum working pressure: 350 bar

Oil particle monitor of working fluid cleanliness class LDP100 Oil particle monitor of working fluid cleanliness class LDP100

IFM

Product code: 5136

sensitivity: 4, 6, 14, 21 µm

measurement error: ± 1%

maximum working pressure: 420 bar

Visual flow indicators SCF Visual flow indicators SCF

F.lli Giacomello

Product code: 6609

G1/4–G1 1/4

measuring range: 0.6-60 l/min

maximum working pressure: 30 bar

In-line contamination monitor ICM - 2.0 In-line contamination monitor ICM - 2.0

MPFiltri

Product code: 5477

sensitivity: 4, 6, 14, 21, 25, 38, 50, 70 µm

monitoring time: 10–3600 s

measurement accuracy: ± 0,5% (4, 6, 14 µm), ± 1% (21, 25, 38, 50, 70 µm)

maximum working pressure: 420 bar

In-line contamination Monitor ICM In-line contamination Monitor ICM

MPFiltri

Product code: 5138

sensitivity: 4, 6, 14, 21, 25, 38, 50, 70 µm

monitoring time: 10–3600 s

measurement error: ± 0,5% (4, 6, 14 µm), ± 1% (21, 25, 38, 50, 70 µm)

maximum working pressure: 400 bar

Electronic flow rate transmitter EVS3100 Electronic flow rate transmitter EVS3100

Hydac

Product code: 3166

internal thread: G1/4

measuring range: 1.2–600 l/min

maximum working pressure: 400 bar

Electronic flow rate transmitter EVS3100-H/EVS3110-H Electronic flow rate transmitter EVS3100-H/EVS3110-H

Hydac

Product code: 3167

internal thread: G1/4

measuring range: 1.2–600 l/min

maximum working pressure: 400 bar

Electronic flow transmitter HFT2100 Electronic flow transmitter HFT2100

Hydac

Product code: 3168

internal thread: G1/4–G1

measuring range: 0.5–110 l/min

maximum working pressure: 350 bar

Electronic flow transmitter HFT2500 for water Electronic flow transmitter HFT2500 for water

Hydac

Product code: 3169

internal thread: G1/4–G1 1/2

measuring range: 0.005–250 l/min

maximum working pressure: 350 bar

Contamination Sensor CS 1000 Contamination Sensor CS 1000

Hydac

Product code: 5141

sensitivity: 4, 6, 14, 21 µm

measurement accuracy: ± 0.5%

maximum working pressure: 350 bar

Contamination Sensor CS2000 Contamination Sensor CS2000

Hydac

Product code: 5140

sensitivity: 2, 4, 5, 6, 14, 15, 21, 25, 50 µm

measurement accuracy: ± 0.5%

maximum working pressure: 350 bar

Oil Condition Sensor HLB 1300 Oil Condition Sensor HLB 1300

Hydac

Product code: 5139

G3/4

maximum working pressure: 50 bar

measurement accuracy: ± 3%

Flow detector FD Flow detector FD

Bucher

Product code: 2649

G1/2

measuring range: 0.4–160 l/min

maximum working pressure: 420 bar

Flow meters MPVB Flow meters MPVB

Seim

Product code: 1636

internal thread: G3/4, G1 1/4, G1 1/2

measuring range: 0.9–900 l/min

maximum working pressure: 400 bar

Flow indicator ZV Flow indicator ZV

Fox

Product code: 4288

internal thread: G1/2, G 3/4, G1

measuring range: 0.2–130 l/min

maximum working pressure: 200 bar

Flow indicator ZVL Flow indicator ZVL

Fox

Product code: 4287

internal thread: G1/2

measuring range: 0–20 l/min

maximum working pressure: 150 bar

Flow meters SVC Flow meters SVC

Kracht

Product code: 5296

internal thread: G3/4, G1, G1 1/2, G3

SAE 3/4 ", 1", 1 1/2", 3", 4"

measuring range: 0.4–3750 l/min

maximum working pressure: 400 bar

Flow meters VC Flow meters VC

Kracht

Product code: 5294

internal thread: G1/8–G1

measuring range: 0.008–700 l/min

maximum working pressure: 400 bar

Flow meters VCA/VCN/VCG Flow meters VCA/VCN/VCG

Kracht

Product code: 5293

internal thread: G1/4–G1

measuring range: 0.02–240 l/min

maximum working pressure: 200 bar

Flow meters VCL 0,1 Flow meters VCL 0,1

Kracht

Product code: 5292

internal thread: G3/8

measuring range: 0.05–2 l/min

maximum working pressure: 400 bar

Turbine flow meters TM consumption explosion proof (ATEX) Turbine flow meters TM consumption explosion proof (ATEX)

Kracht

Product code: 5295

M20x1.5, M24x1.5, M30x2, M36x3, M52x2

DN flanges 10–400

measuring range: 0.92–66667 l/min

maximum working pressure: 400 bar

Valve Position Indicator VOLUMEC 5 Valve Position Indicator VOLUMEC 5

Kracht

Product code: 5291

maximum working pressure: 300 bar

maximum flow rate: 150 l/min

Valve Position Indicator VOLUMEC / VOLUTRONIC Valve Position Indicator VOLUMEC / VOLUTRONIC

Kracht

Product code: 5290

maximum working pressure: 400 bar

maximum flow rate:16 l/min

Control-measuring devices systems

Functional purpose of control-measuring device for hydraulic system

Control-measuring devices are special units which help you to get information about on the state of technological processes in the hydraulic system by measuring their parameters. These devices also serve for controlling different  technical processes, increase productivity and guarantee safety work of hydraulic system.

Processing and measuring hydraulic parameters is a must in order to minimize the risk of equipment failures.

In the range of control-measuring devices for hydraulic systems our company offers:

  • hydraulic pressure sensors;
  • flow sensors;
  • temperature sensors;
  • oil level sensors;
  • cleanliness class sensors;
  • moisture content sensors;
  • flow speed sensors;
  • hydraulic pressure relay;
  • temperature relay;
  • oil level relay;
  • viscometers;
  • inductive sensors;
  • limit switches;
  • portable measuring instruments;
  • digital displays.