We show installing the adapter type Serv-clip 2 in a hydraulic system

Mounting the Serv-Clip type adapter in the hydraulic system allows you to quickly create control points in places where this is not provided for by the design. Without draining the working fluid, cutting and welding.

In three minutes, the test fitting is installed on a metal pipeline with a diameter from 10 to 42 mm and makes a hole in it for diagnostic and hydraulic system service:

— pressure measuring,

— nstallation of pressure gauges or electric sensors and pressure, flow and temperature switches;

— oil sampling;

— determination of oil purity class;

— air release.

Model Serv-Clip 1 uses for installation of pipeline during the hydraulic system with working pressure operation.

A punch is screwed in with a 22 mm wrench until the pipe wall is completely pierced with a special needle in the nozzle design.

After this required sensor is screwed into the fitting.

Technical capabilities:

— diameter of the pipeline: 10 – 42 mm;

— maximum hydraulic system working pressure: 630 bar;

— maximum pipe wall thickness: 5 mm;

— adapter operating temperature: -40 ° C - +120 ° C.

We show installing the adapter type Serv-clip 2  in a hydraulic system

Model Serv-Clip 2 is used in hydraulic system without pressure.

A 22 mm wrench screws the mounting nozzle in place. A special needle in the construction of the fitting punctures a hole in the pipe wall, after which it is removed back. Instead of a “hole punch”, the required sensor is screwed into the fitting.

Technical capabilities:

— diameter of the pipeline: 10 – 42 mm;

— maximum hydraulic system working pressure: 630 bar;

— maximum pipe wall thickness: 5 mm;

— adapter operating temperature: -40 ° C – +120 ° C

Mounting adapters Serv-Clip type are fixed on the pipeline once, and are used throughout the entire life cycle of your hydraulic, lubricating and refrigerating equipment.

In the video, we show in detail the installation of the Serv-Clip 2 adapter:


 