Hydac
3/4–16 UNF
maximum working pressure: 350 bar
maximum flow rate: 60 l/min
7/8–14 UNF
maximum working pressure: 350 bar
maximum flow rate: 100 l/min
maximum flow rate: 5 l/min
filtration rating: 2, 5, 10, 20 µm
maximum working pressure: 8 bar
maximum flow rate: 18 l/min
filtration rating: 2, 5, 10, 20 µm
maximum working pressure: 5 bar
maximum flow rate: 114 l/min
filtration rating: 2, 5, 10, 20 µm
maximum working pressure: 5 bar
maximum flow rate: 15 l/min
tank capacity: 70 l
filtration rating: 2, 4, 5, 10, 20 µm
maximum working pressure: 3.5 bar
maximum flow rate: 100 l/min
filtration rating: 3, 5, 10, 20, 40 µm
maximum working pressure: 10 bar
maximum flow rate: 40 l/min
barrel capacity: 200 l
filtration rating: 3, 5, 10, 20, 40 µm
maximum working pressure: 4.5 bar
maximum flow rate: 40 l/min
filtration rating: 3, 5, 10, 20, 40 µm
maximum working pressure: 4.5 bar
maximum flow rate: 15 l/min
filtration rating: 1, 2, 5, 10, 20 µm
maximum working pressure: 4.5 bar
maximum flow rate: 40 l/min
filtration rating: 3, 5, 10, 20, 40 µm
maximum working pressure: 4.5 bar
sensitivity: 4, 6, 14, 21 µm
flow measurement error: ± 0.5%
maximum working pressure: 345 bar
sensitivity: 2–50 µm
flow measurement error: ± 0.5%
maximum working pressure: 350 bar
sensitivity: 2–100 µm
flow measurement error: ± 0.5%
maximum working pressure: 350 bar
sensitivity: 4, 5, 6, 14, 15, 21, 25 µm
maximum working pressure: 120 bar
sensitivity: 2–50 µm
maximum working pressure: 120 bar
sensitivity: 4–100 µm
monitoring time: 75 s
with indicator of contamination CS and the water content sensor AS
sensitivity: 4, 6, 14, 21 µm
flow measurement error: ± 0.5%
maximum working pressure: 350 bar
sensitivity: 2, 4, 5, 6, 14, 15, 21, 25, 50 µm
flow measurement error: ± 0.5%
maximum working pressure: 350 bar
G3/4
flow measurement error: ± 3%
maximum working pressure: 50 bar
G3/8
flow measurement error: ± 3%
maximum working pressure: 50 bar
flow measurement error: ± 2%
temperature measuring range: -20–120 °C
maximum working pressure: 10 bar
G3/8
flow measurement error: ± 3%
maximum working pressure: 50 bar
flow measurement error: ± 2%
maximum working pressure: 10 bar
sensitivity 70, 100, 200 µm
maximum flow rate: 200 l/min
maximum working pressure: 20 bar
for using with mobile monitoring system "FCU 8000"
for CS1000 purity grade sensors, moisture sensors and AS1000 metal particles content sensors MCS1000
maximum flow rate: 40 l/min
filtration rating: 3, 5, 10, 20, 40 µm
maximum working pressure: 4.5 bar
maximum flow rate: 15 l/min
filtration rating: 3, 5, 10, 20 µm
maximum working pressure: 3.5 bar
filtration rating: 1, 3, 5, 10, 20, 30, 40, 50, 70, 90 µm
maximum working pressure: 5 bar
maximum flow rate: 15 l/min
maximum flow rate: 100 l/min
filtration rating: 3, 5, 10, 20, 40 µm
maximum working pressure: 10 bar
filtration rating: 3, 5, 10, 20, 40 µm
maximum working pressure: 3.5 bar
maximum flow rate: 20 l/min
tank capacity: 1.8–8.4 l (plastic)
with a gear pump
maximum pump displacement 10 cm3/rev
maximum pressure: 250 bar
maximum motor power: 3 kW
tank capacity: 1.2–7.8 l (plastic)
with a gear pump
maximum pump displacement: 10 cm3/rev
maximum pressure: 250 bar
maximum motor power: 3 kW
tank capacity: 1.1–7 l (plastic)
with a radial piston pump
maximum pressure: 500 bar
maximum motor power: 1.6 kW
maximum flow rate: 15 l/min
filtration rating: 2, 3, 5, 10, 20 µm
maximum working pressure: 4.5 bar
maximum flow rate: 60 l/min
filtration rating: 2, 10, 20, 30 µm
maximum working pressure: 5 bar
filtration rating: 3 µm
maximum flow rate: 30000 l/min
filtration rating: 3 µm
maximum flow rate: 270 l/min
filtration rating: 1, 2, 3 µm
maximum flow rate: 1800 l/min
filtration rating: 3 µm
maximum flow rate: 1200 l/min
filtration rating: 3 µm
maximum flow rate: 5500 l/min
length : 76, 127, 176, 254, 381 mm
with temperature relay TS